Skip to content
Data Center RFP

Data center RFP template you can copy and send

Updated November 2026

This data center RFP template is a complete request you can copy into your own document, fill in where you see brackets and send to a short list of providers. It has 13 sections, a price sheet every bidder fills in the same way, and a checklist to run before it goes out.

Not sure of your load, density or dates yet? The RFP Scope Planner on our home page turns eight answers into a scope and a dated timeline.

If you would rather not write it yourself, send us the requirement and we will write the RFP, issue it and compare the responses with you.

Send Us Your Requirement

On this page
  1. 1How to use this template
  2. 2The template
  3. 3Colocation RFP template: the price sheet
  4. 4Data center RFP checklist
  5. 5Colocation RFP checklist for wholesale, AI or build to suit
  6. 6Questions to add to sections 9 and 10
  7. 7Data center RFP template questions
  8. 8Sources

1How to use this template

  1. Fill in every bracket, or delete the line if it does not apply. A provider will answer whatever you leave in, so a stray bracket costs you a round of questions.
  2. Keep the section numbers. Ask providers to answer in the same order, so you can read five responses side by side.
  3. Put your quantities on the price sheet before you send it. Providers fill in prices only.
  4. Send it to three to six providers that can serve your size, density and date.
  5. Decide how you will score the responses before they arrive. Our colocation pricing comparison guide has the weights and a calculator.

2The template

1.Invitation and key dates

[Company name] invites a short list of providers to respond to this request for proposal for data center space and power in [market or markets].

  • Intent to respond due: [date]
  • Written questions due: [date]
  • Our answers sent to all bidders by: [date]
  • Responses due: [date, time and time zone], by email to [name, email address]
  • Shortlist decision: [date]
  • Target signature: [date]
  • Required ready-for-service date: [date]

2.About us and how we will decide

  • Company: [legal name, industry, headquarters city]
  • What this space will run: [production, disaster recovery, AI training or inference, back office, other]
  • Decision owner: [role]. Evaluation team: [roles from IT, security, finance, procurement]
  • Contracting entity: [legal entity that will sign]
  • We will score responses on the criteria in section 13. Price is one criterion, not the only one.

3.Requirement summary

ItemAt startAt full buildNotes
IT load (kW)[ ][ ]Measured draw, not nameplate
Cabinets, cage or suite[ ][ ][cabinet count or square feet]
Typical kW per cabinet[ ][ ]
Highest kW per cabinet[ ][ ][which systems]
Ready-for-service date[ ][ ]
Term[months][renewal options wanted]

4.Location

  • Markets in order of preference: [1], [2], [3]
  • Distance or latency limit from [existing site or office]: [miles or milliseconds]
  • Minimum separation from our other site, if this is for recovery: [miles]
  • Name the building address and the hall or suite you are offering, and say whether it is built today or planned.

5.Power

  • Feeds: A and B power to every cabinet, [voltage, phase and amperage per circuit]
  • Billing basis we prefer: [committed kW, metered energy, or per circuit]. Quote ours and tell us if you also offer another.
  • Redundancy expected for UPS and generators: [N+1 or 2N]
  • Generator run time on fuel stored on site: [hours]
  • State the power you can deliver to our space on the ready-for-service date and how it is secured: energized today, under construction, or waiting on the utility.

6.Cooling and density

  • Typical and highest kW per cabinet: see section 3
  • Cooling we expect: [air with containment, rear-door heat exchangers, direct-to-chip liquid]
  • Inlet temperature range we require at the cabinet: [range]
  • If liquid cooling: say who supplies, owns and maintains the coolant distribution units, the manifolds and the secondary loop, and who is responsible for a leak.

7.Space and building

  • Cabinet size: [rack units, width and depth]. Provider cabinets or ours: [ ]
  • Space type: [cabinets in a shared row, private cage, private suite]
  • Floor loading needed for our heaviest cabinet: [pounds per square foot]
  • Shipping, receiving, storage and staging space needed for the move: [ ]
  • Expansion: hold [cabinets, kW or square feet] next to our space for [months]. State the cost of holding it.

8.Network and interconnection

  • Carriers we need on-net in the building: [names, or "at least two diverse carriers"]
  • Cloud on-ramps: [platforms and port speeds]
  • Diverse fiber entrances and meet-me rooms: [required or preferred]
  • Cross-connects at start: [count and type: single-mode fiber, multimode, copper]
  • We [will or will not] bring a carrier that is not on-net. State the process and cost.
  • Private links needed to: [existing site, office, cloud region]

9.Security and compliance

  • Frameworks we must meet: [SOC 2, ISO 27001, PCI DSS, HIPAA, other]
  • Send your most recent audit reports, with the period each covers and confirmation that this building is in scope.
  • Physical controls we expect: [layers of access, biometrics, cameras on our space, visitor escort, log retention period]
  • Incident notice: state how and how fast you will tell us about a security event affecting our space.

10.Operations and support

  • Remote hands: scope, hourly rate, billing increment, hours included each month
  • Response time you commit to for urgent and routine requests
  • Staffing on site, by shift
  • Notice you give before maintenance that could affect power or cooling
  • Outages in this building in the past [five] years that affected customer power, cooling or network: date, duration and cause

11.Contract terms

  • Term wanted: [months]. Renewal: [options]. Notice period we can accept: [ ]
  • Annual increases: state which charges rise, by how much, and whether there is a cap
  • Expansion and contraction rights, and any right of first refusal on adjacent space
  • Service levels for power, cooling and network, the credit for each breach, and whether credits are the only remedy
  • Remedy if the ready-for-service date is missed
  • Whether you can relocate us during the term, and who pays
  • Liability cap, insurance we must carry, and assignment terms
  • Exit: time to remove equipment, removal charges, and holdover terms
  • Include your standard agreement, service level agreement and order form with your response.

12.Pricing

Complete the attached price sheet. Do not change its rows or units. Put anything that does not fit in the notes column. State how long your pricing is valid: we need at least [90] days.

13.Response instructions and evaluation

  • Answer in the order of this document and keep our numbering.
  • Send one PDF plus the price sheet in its original format.
  • Send all questions to [email address] by [date]. We will send every question and answer to every bidder without naming who asked.
  • Please do not contact other staff about this request while it is open.
  • We will score responses on: [total cost over the term, power and cooling fit, delivery date, network, contract terms, security and compliance, operations]. Weights: [ ].
  • We will keep your response confidential. [An NDA is attached / available on request.]
  • This request is not an offer or a commitment. Nothing is binding until both parties sign an agreement.
  • Attachments: price sheet, equipment list, high-level network diagram, [NDA], [compliance requirements].

3Colocation RFP template: the price sheet

One price sheet, filled in the same way by every bidder, does more for a fair comparison than any other part of the RFP. Your quantities go in before you send it. Providers fill in the charges.

LineUnit to quoteYour quantityOne-timeMonthlyRises each year?Notes
Space: cabinets, cage or suitePer cabinet, or per square foot[ ]
Committed powerPer kW per month[ ]
Energy billed by meterPer kWh, plus any multiplier[estimate]State the multiplier
Power circuitsPer circuit: voltage, amps, phase[ ]
Cage build or suite fit-outOne-time[ ]
Cabinet installationPer cabinet, one-time[ ]
Cross-connect, single-mode fiberPer connection[ ]
Cross-connect, copperPer connection[ ]
Cloud on-ramp or fabric portPer port, by speed[ ]
Internet bandwidth (if offered)Per Mbps committed[ ]Optional
Remote handsPer hour, with billing increment[ ]
Remote hands hours includedHours per month
After-hours remote handsPer hour
Shipping, receiving and storagePer shipment, per pallet per month[ ]
Access badges and escortsPer badge, per escort hour[ ]
Taxes and pass-through feesPercent or per lineList each one
Deposit or letter of creditAmountWhen returned
Free months offeredNumber of months
Early terminationFormula
Removal at exitOne-time

Download the price sheet (CSV)

Opens in Excel, Google Sheets or Numbers.

4Data center RFP checklist

Run this before the RFP goes out and while bids are open. It is also in the printable version.

Before you write

Before you send

While bids are open

When responses arrive

Download the checklist (CSV)

5Colocation RFP checklist for wholesale, AI or build to suit

The template above fits most retail colocation needs. Change these parts for larger or denser requirements.

Source: CBRE Research, North America Data Center Trends H1 2026, Aug 27 2026. cbre.com

6Questions to add to sections 9 and 10

Add the provider questions that would change your decision (power delivery date, density limits, carrier list, compliance reports, escalators, exit terms) to the matching sections, so every bid answers them in the same order.

Want us to fill it in and run it?

Send us the requirement. We reply by email within 24 hours with the questions we need answered and a plan for the RFP. Buyers pay nothing for placement: the provider you sign with pays us.

Send Us Your Requirement

7Data center RFP template questions

What format should providers send their responses in?

Ask for one PDF that answers in the order of your RFP, plus your price sheet returned in its original format. Matching section numbers let you read the responses side by side, and an untouched price sheet lets you compare charges line by line.

How many providers should receive the RFP?

Three to six is enough for most requirements. Each extra bidder adds questions to answer and responses to score, and providers put less work into an RFP when they can see it went to a long list.

Should we include our budget in the RFP?

Usually not. A stated budget tends to become the price. State your quantities, your dates and your terms instead, and let the price sheet show what each provider charges.

Can we edit and reuse this template?

Yes. Copy it, print it or download the price sheet, change any part of it and use it as often as you like. You don't need to give us your details to use it.

How is this different from the RFP pack the planner creates?

This page gives you the full template to fill in by hand. The RFP Scope Planner on our home page asks eight questions and builds a scope, a dated timeline and the questions that matter for your type of deployment, and its RFP pack is built from your answers.

Can you write and run the RFP for us?

Yes. Send us your requirement and we will reply by email within 24 hours. We write the RFP, send it to providers that fit once you agree the list, and compare the responses with you.

8Sources

Send Us Your Requirement